AHP06 Series Double Drive Single Acting
Choice of 9 ratios. Flows to 19.9 L/min. Choice of wetted materials. Pressures to 75,000 psi(5171 bar)Drive pressure 30 to 150 psi (2 to 10.3 bar)
Related attachments:
No content available yet.
AHP06 Series Double Drive Single Acting
Features
Choice of 9 ratios.
Flows to 19.9 L/min.
Choice of wetted materials.
Pressures to 75,000 psi(5171 bar)Drive pressure 30 to 150 psi (2 to 10.3 bar)
Model and Technical Specifications
Pump Model code | Max.Out Press | Actual Ratio | Dis./Cycle | Max.Flow | Inlet Port | Outlet Port | Air Drive Port |
AHP06-2S-20 | 3200 psi (22.1 MPa) | 27:1 | 66.4mL | 19.9L/min | 1"FNPT | 1/2" FNPT | 3/4" FNPT |
AHP06-2S-30 | 4800 psi (33.1 MPa) | 35:1 | 44.3mL | 13.3L/min | 1"FNPT | 1/2" FNPT | 3/4" FNPT |
AHP06-2S-50 | 8000 psi (55.1 MPa) | 60:1 | 26.6mL | 8L/min | 1/2" FNPT | 1/2" FNPT | 3/4" FNPT |
AHP06-2S-70 | 11,000 psi (75.9 MPa) | 90:1 | 19.0mL | 5.7L/min | 1/2" FNPT | 1/2" FNPT | 3/4" FNPT |
AHP06-2S-120 | 19,000 psi (131 MPa) | 144:1 | 11.0mL | 3.3L/min | 1/2" FNPT | 1/2" FNPT | 3/4" FNPT |
AHP06-2S-200 | 33,000 psi (227.6 MPa) | 240:1 | 6.7mL | 1.5L/min | 1/2" FNPT | 3/8" HF | 3/4" FNPT |
AHP06-2S-300 | 50,000 psi (344.8 MPa) | 360:1 | 4.5mL | 1L/min | 1/2" FNPT | 3/8" HF | 3/4" FNPT |
AHP06-2S-450 | 70,000 psi (482.8 MPa) | 540:1 | 3.0mL | 0.7L/min | 1/2" FNPT | 1/4" HF | 3/4" FNPT |
AHP06-2S-600 | 75,000 psi (517.2 MPa) | 720:1 | 2.3mL | 0.5L/min | 1/2" FNPT | 1/4" HF | 3/4" FNPT |
HF means female high pressure connection,The max outlet pressure is based on the air drive pressure at 125psi(0.86MPa): The max flow rate is based on outlet pressure at 0 psi (working empty)
Dimensions

Performance Curve
Note: The shaded area in the diagram indicates excessivecirculation rate or pressure. Use intermittently.